Protective clothing worn in emergency medical services (EMS) is not washed at home. TRBA 250 prohibits taking worn protective clothing home, and DGUV Rule 105-003 recommends a commercial laundry holding the RAL-GZ 992/2 quality mark that uses disinfecting wash processes from the RKI list covering activity ranges A and B. The employer pays for cleaning and disinfection.

Contents

As of 26 November 2026. Based on TRBA 250 (November 2025 edition), DGUV Rule 105-003 (May 2016 edition), the 19th edition of the RKI list (as of 31 March 2026) and framework hygiene plans from Rhineland-Palatinate, Saxony and Lower Saxony.

May EMS clothing be washed at home?

No. Two sets of rules say so:

  • TRBA 250, section 4.2.7(4): Employees must not take worn protective clothing or contaminated work clothing home. TRBA 250, the German Technical Rule for Biological Agents in healthcare and welfare, expressly covers EMS and patient transport in section 1. Employers who follow it can assume they meet the Biological Agents Ordinance (BioStoffV).
  • DGUV Rule 105-003, section 4.6: To protect third parties, EMS protective clothing must not be washed at home. The rule refers to TRBA 250 on this point.

The reason is the protection of family members and housemates. EMS clothing can carry pathogens, and according to TRBA 250 (section 2.3) contamination is not always visible to the naked eye. The same definition requires employers to make sure that contaminated private clothing is not taken home for cleaning either.

The framework hygiene plan for Rhineland-Palatinate (version 5.0, as of 1 February 2026) goes further: duty clothing such as trousers, polo shirts or sweatshirts stays at the station and is only put on and taken off there. The plan rules out washing it in a private household because in EMS this clothing forms part of the protective clothing.

Who pays for cleaning and disinfection?

The employer. This follows from statute and is confirmed by the ordinance, the technical rule and the DGUV rule. The table shows what applies and how binding it is.

Who What Source Type of requirement
Employer must not pass the costs of health and safety measures on to employees Occupational Safety and Health Act (ArbSchG), section 3(3) statute
Employer cleans, maintains and repairs PPE provided, including protective clothing; provides a way to take it off and store it apart from other clothing BioStoffV, section 9(3) nos. 5 and 6 ordinance, for work beyond risk group 1
Employer cleans reusable PPE with a disinfecting process after use TRBA 250, section 4.2.6(3) technical rule with presumption of conformity
Employees do not take worn protective clothing home TRBA 250, section 4.2.7(4) technical rule with presumption of conformity
Employer provides PPE free of charge and bears the costs of maintenance, cleaning and disinfection DGUV Rule 105-003, section 2.4 recommendation of the statutory accident insurance
Service provider or EMS area sets change intervals, collection and reprocessing hygiene plan, state framework hygiene plan varies by state and organisation

DGUV Rule 105-003 is a recommendation. Other solutions that are at least as safe are permitted (section 1). Anyone who falls below its recommendations when selecting PPE must document the reasons under section 2.3. The basis for this is the risk assessment.

Which wash process do the rules require?

Section 4.6 of DGUV Rule 105-003 requires protective clothing, removable insulating liners, trousers and work clothing in EMS to be capable of disinfection. They should be suitable for disinfecting wash processes from the RKI list. The garment maker must recommend disinfection processes from the RKI list covering activity ranges A and B.

The Robert Koch Institute (RKI), Germany's public health institute, keeps this list under section 18 of the Infection Protection Act for disinfection ordered by the authorities. The current edition is the 19th, as of 31 March 2026. It labels efficacy with letters:

Activity range Meaning according to the RKI list
A kills vegetative bacteria including mycobacteria, and fungi including fungal spores
B inactivates viruses, both enveloped and non-enveloped (definition “virucidal”)
C kills anthrax spores
D kills spores of the pathogens causing gas gangrene and tetanus; this requires sterilisation

For disinfecting laundry in washing machines, the list distinguishes two groups:

  • Thermal processes: 85 °C for 15 minutes or 90 °C for 10 minutes, liquor ratio 1:4 to 1:5, activity range AB.
  • Chemothermal processes: detergent plus disinfectant at lower temperatures, often 40, 60 or 70 °C. Each process is listed with product, dosage, temperature, contact time and liquor ratio and is only effective in exactly that form. Some processes cover activity range A only. According to the list, the processes based on peroxygen compounds are not suitable for laundry noticeably soiled with blood.

Whether a garment tolerates thermal disinfection at 85 or 90 °C or only a chemothermal process depends on its materials, and the manufacturer's information has to say which. For retroreflective material, section 4.2.3 of DGUV Rule 105-003 requires the retroreflection values to hold after industrial care under ISO 15797 and after the prescribed disinfecting wash. ISO 15797:2017 sets out test procedures for workwear intended for industrial laundering. It is not a wash recipe for the laundry.

Regular protective clothing does not need to be sterile after washing. DGUV Rule 105-003 states this at the end of section 4.6.

Laundry, a machine at the station, or at home?

The decision can be made in three steps:

  1. At home: ruled out by TRBA 250 and DGUV Rule 105-003.
  2. Commercial laundry: the standard route. DGUV Rule 105-003 recommends that washing, drying and re-proofing be carried out wherever possible by a commercial laundry rated under RAL-GZ 992/2 that works to the RKI requirements. It points to validatable processes with consistent washing and drying conditions, and to the option of re-proofing or repairing garments in the same place.
  3. Own washing machine at the station: only under conditions. DGUV Rule 105-003 considers this hard to achieve because of the RKI requirements for laundry from healthcare settings.

Two sources show what “hard to achieve” means in practice. Section 3.1 of the RKI list requires the machine to hold concentration, liquor ratio and temperature for the entire contact time; professional drum washers can do this, domestic washing machines are generally not suitable. Section 3.6 of the Rhineland-Palatinate framework plan lists the following for in-house reprocessing, among other things:

  • a reprocessing room with separate clean and unclean sides, a hand-wash station and dispensers for soap and hand disinfectant,
  • an industrial washing machine that maintains and records all parameters of the listed programmes,
  • tested and listed disinfecting wash programmes, plus re-proofing as specified by the textile manufacturer,
  • protective clothing for staff loading the machine,
  • a microbiological efficacy check of all disinfection programmes with bioindicators every six months by an independent institute.

According to the quality association for textile services (Gütegemeinschaft Verantwortungsvoller Textilservice), the RAL-GZ 992/2 quality mark for hospital linen serves as evidence that a laundry meets the RKI requirements for outsourcing laundry. Only laundries that have held the RAL-GZ 992/1 mark for more than a year can obtain it, and compliance is monitored by the Hohenstein research centre. Annex 2 of DGUV Rule 105-003 states that since 2003 quality-mark laundries have used only processes covering activity ranges A and B for healthcare laundry, explicitly including EMS clothing.

For a laundry tender, this means: ask for the current RAL-GZ 992/2 hygiene certificate and check the intended process against the manufacturer's information for your clothing. For more on procurement, see the guide Sourcing protective clothing for EMS.

What must the manufacturer's information say about care?

Under section 4.7 of DGUV Rule 105-003, protective clothing must come with manufacturer's information in line with EN ISO 13688. For care, these minimum details matter:

Information What you need it for
care instructions with full directions for washing, dry cleaning and decontamination checking against the laundry's process
recommended disinfection processes from the RKI list, activity ranges A and B an obligation of the garment maker under DGUV Rule 105-003
maximum number of care cycles, if limited, after the word “max.” next to the care label planning replacement and reordering, see Replacing high-visibility clothing
note on chlorine-free washing instruction to the laundry
storage and maximum intervals for inspection clothing store and inspection schedule
limits of use, warning against misuse briefing crews

The label example in section 4.7.2 of the rule also shows the care symbol for industrial laundering under ISO 30023, a pictogram for the RKI disinfecting wash process with activity range A + B, and the book symbol pointing to the manufacturer's information. The label must stay legible for as long as the garment lasts. How to read the high-visibility class on the same label is explained in the guide High-visibility class 2 or 3 for EMS.

DGUV Information 212-016 on high-visibility clothing does not apply to EMS but is a useful reference: under section 8.3, the laundry carries out a visual check after every wash, and wearers also check the garment before each use.

How often is clothing changed? What state framework plans say

There is no nationwide change interval. It is set by the service provider's hygiene plan and, depending on the federal state, by a framework hygiene plan. Two examples:

Rhineland-Palatinate (version 5.0, 1 February 2026) Saxony (joint working group of several states, March 2011)
Duty clothing (trousers, shirt, cap) daily, when visibly soiled and after an infectious transport without protective clothing work clothing is only put on at the workplace
Duty jackets and vests when visibly soiled, at least monthly, after an infectious transport without protective clothing reusable protective clothing daily or when soiled
Soaked clothing additionally in a tear-proof, liquid-tight bag labelled as infectious laundry not specified
Reprocessing external provider with hygiene approval, or in-house under section 3.6; both must ensure re-proofing disinfecting wash process with agents from the VAH list, in-house or by an external laundry
Storage duty jacket kept apart from private clothing protective clothing kept apart from other clothing

The Rhineland-Palatinate plan names hardshell and softshell jackets explicitly. The Saxon plan is older and still refers to GUV-R 2106, the former number of DGUV Rule 105-003. It relies on the VAH list of the German Association for Applied Hygiene, which is intended for routine, preventive disinfection; the RKI list applies to disinfection ordered by the authorities. Check with your organisation's hygiene officer which list your hygiene plan specifies.

On the road, TRBA 250 (section 4.1.7(3)) applies: if meal breaks are needed during mobile operations, contaminated work clothing, especially the jacket, must be put down at a sufficient distance from staff.

Frequently asked questions

Does this also apply to volunteers?

Yes. Under section 1 of TRBA 250, volunteers and persons covered by the statutory accident insurance are brought within its scope through the statutes of the accident insurance institutions. DGUV Rule 105-003 consistently refers to insured persons, who must be provided with PPE free of charge.

Does DGUV Rule 105-003 cover water, mountain and air rescue?

Not the specialist PPE used there. Section 1 expressly excludes mountain rescue, water rescue, sea rescue, air rescue, hazardous-substance incidents and technical rescue. TRBA 250, by contrast, applies wherever people are medically examined, treated, transported or cared for, and expressly names EMS, patient transport and medical first-response services (sanitätsdienstliche Versorgung).

Are “procedures A, B, C” in a hygiene plan the same as the RKI activity ranges?

Not necessarily. The Lower Saxony recommendation on protection and hygiene measures in EMS (as of 15 February 2024), for example, assigns its own procedures A, B and C to surface disinfectants according to efficacy level. These letters mean something different from activity ranges A to D in the RKI list, which DGUV Rule 105-003 refers to for laundry.

What applies to high-visibility clothing worn outside EMS?

DGUV Information 212-016 on high-visibility clothing (November 2025 edition) excludes EMS from its scope. For other sectors, section 8.3 states that high-visibility clothing contaminated with biological agents or hazardous substances must not be washed privately, and that a laundry with the RAL 992-2 quality mark using a recognised wash process is particularly suitable.

Standards are protected by copyright and available from DIN Media or ISO. This guide explains their content in its own words and replaces neither your organisation's hygiene plan nor the risk assessment.

Sources (13)

  1. DGUV Rule 105-003 “Use of personal protective equipment in emergency medical services”, May 2016 editionchecked 26 November 2026
  2. DGUV Rule 105-003, PDF, sections 1, 2.3, 2.4, 4.2.3, 4.6, 4.7 and Annex 2checked 26 November 2026
  3. TRBA 250 “Biological agents in healthcare and welfare”, November 2025 edition (GMBl no. 34-37 of 10 November 2025, first amendment GMBl no. 38 of 14 November 2025), BGW printchecked 26 November 2026
  4. German Occupational Safety and Health Act, section 3checked 26 November 2026
  5. German Biological Agents Ordinance, section 9checked 26 November 2026
  6. Robert Koch Institute, list of tested and approved disinfectants and disinfection processes, 19th edition, as of 31 March 2026checked 26 November 2026
  7. Robert Koch Institute, overview page on disinfectants and processeschecked 26 November 2026
  8. Gütegemeinschaft Verantwortungsvoller Textilservice, RAL-GZ 992/2 hospital linenchecked 26 November 2026
  9. ISO 15797:2017, catalogue entrychecked 26 November 2026
  10. DGUV Information 212-016 “Warnkleidung”, November 2025 editionchecked 26 November 2026
  11. Framework hygiene plan for emergency rescue and patient transport, Rhineland-Palatinate, version 5.0, as of 1 February 2026checked 26 November 2026
  12. Framework hygiene plan for emergency rescue and patient transport services, March 2011 (Saxony)checked 26 November 2026
  13. Lower Saxony, recommendation on protection and hygiene measures in EMS, as of 15 February 2024checked 26 November 2026

This article gives a general overview. It does not replace the text of the standard or the risk assessment in your organisation. For any product, its declaration of conformity and the manufacturer's information are binding. If you notice a mistake, please let us know.

Terms in this guide

  • DGUV Rule 105-003

    DGUV Rule 105-003 “Use of personal protective equipment in emergency medical services” is a German Social Accident Insurance rule, edition May 2016. It describes which protective clothing EMS providers should select, such as high-visibility clothing to EN ISO 20471 of at least class 2, class 3 weather protection to DIN EN 343:2010 and disinfecting laundry per the RKI list.

  • ISO 15797 (industrial laundering)

    ISO 15797 is the international standard describing industrial washing and finishing procedures used to test workwear in the laboratory. The current edition ISO 15797:2017 applies in Europe as EN ISO 15797:2018 and in Germany as DIN EN ISO 15797:2018-05. DGUV Rule 105-003 requires high-visibility clothing in emergency medical services (EMS) to keep its retroreflective performance after such industrial laundering.

  • EN ISO 13688

    EN ISO 13688 is the basic standard for protective clothing. It sets general requirements for ergonomics, innocuousness, size designation, ageing, compatibility and marking, and for the information supplied by the manufacturer. The valid version is EN ISO 13688:2013+A1:2021, in Germany DIN EN ISO 13688:2022-04; it is applied together with a performance standard such as EN ISO 20471.

  • Risk assessment

    A risk assessment is the employer's legal duty under section 5 of the German Occupational Safety and Health Act (ArbSchG) to identify a task's hazards and derive the protective measures needed. In emergency medical services (EMS), DGUV Rule 105-003 makes it the basis for selecting PPE, such as the high-visibility class; results must be documented under section 6 ArbSchG.

  • Retroreflective material

    Retroreflective material returns incoming light, for example from headlamps, back towards its source. On high-visibility clothing to EN ISO 20471 it provides visibility in the dark. The standard requires bands at least 50 mm wide and, depending on the class, 0.10 to 0.20 m² of visible area, measured on the smallest size offered.

  • Hardshell jacket

    A hardshell jacket is a weather-protection jacket with waterproof outer fabric and seams. As PPE, this is tested to EN 343 or, in future, EN ISO 24232 (harmonised since 4 September 2026) and classified. For German EMS, DGUV Rule 105-003 requires waterproofness class 3, breathability class 3 to DIN EN 343:2010 (Ret at most 20 m²·Pa/W) and sealed seams.

  • Softshell jacket

    A softshell jacket is a jacket made of stretchy fabric; the name says nothing about tested rain protection. In emergency medical services (EMS) it is usually high-visibility clothing to EN ISO 20471. It counts as rain protection only if its declaration of conformity names EN 343 or EN ISO 24232; our softshell declarations do not.

  • High-visibility class

    The high-visibility class is the rating of high-visibility clothing under EN ISO 20471 as class 1, 2 or 3. It depends on the minimum visible areas: class 3 requires 0.80 m² of fluorescent background material and 0.20 m² of retroreflective material, class 2 needs 0.50 m² and 0.13 m², and class 1 needs 0.14 m² and 0.10 m².